PET Film Supply Company is a manufacturer of protective film for aluminium profiles, aluminium sheets and ACP panels. The range includes PE and LDPE films for anodized aluminium, powder coated aluminium and PVDF or PE coated panels. Typical thickness is 30-150 mic. Roll size, tack, printing and outdoor grade are selected around extrusion, cutting, transport and installation. Trial rolls should be checked on the actual surface before volume production.

product details

  • Material: PE / LDPE protective film
  • Range: Profile rolls / sheet rolls / ACP panel film
  • Thickness: 30-150 mic typical
  • Colors: Transparent / blue / black and white / custom
  • Formats: Slit rolls / wide rolls / printed rolls
  • Options: Tack / UV grade / logo / direction arrows

Showing all 2 results

Protective film for aluminium is applied once the visible surface has been finished and must stay clean through later work. Profiles, sheets and ACP panels face different risks, so they should not be treated as one generic product group.

A suitable aluminum surface protection film needs enough hold for processing but should still peel cleanly at the planned removal stage. Low tack can lift at cut edges or on textured coatings. Excessive tack can raise peel force after aging and increase residue risk.

Product Range / Covered Products

  • Aluminium profile protection film:Narrow slit rolls for window frames, curtain wall sections and decorative extrusions. An aluminium profile protective film factory should confirm slit width, winding direction, roll flatness and the extrusion-line application method before production.
  • Aluminium sheet protection film:Wide rolls for sheets that will be cut, punched, bent or stacked. For aluminium sheet orders, an aluminum sheet protection film factory should review sheet width, finish and downstream processing before recommending film thickness and tack.
  • ACP panel protection film:Printed or unprinted rolls for aluminium composite panels with PVDF or PE coatings. Direction arrows and removal reminders support facade installation.
  • Application-matched grades:Indoor, short-term outdoor and UV-resistant versions selected by exposure period and removal date.

Selection Guide

Start with the aluminium finish, then review the next process. For profiles, check lamination, sawing, drilling and CNC machining. For sheets, consider cutting, routing and bending. For ACP panels, confirm coating type, sunlight exposure and removal window.

Smooth anodized aluminium and smooth powder coated surfaces often suit low-to-medium tack grades. Rough powder coated, sand-textured or deep matt finishes may need stronger adhesion because the adhesive has less effective contact area. Selecting the highest tack by default is a common mistake. Apply trial rolls to the real substrate under agreed dwell time and aging conditions. Review initial peel force, adhesion growth, residue and edge lifting after cutting or drilling.

Benefits

  • Protects aluminium during extrusion, cutting, storage, transport and installation.
  • Covers slit rolls for profile lines and wide rolls for sheets and ACP panels.
  • Supports clean removal when tack and timing are matched correctly.
  • Reduces edge lifting risk on rough coated surfaces.
  • Allows logos, direction arrows and removal reminders.
  • Supports trial validation before volume supply.

When Should ACP Panel Protective Film Be Removed During an Installation Project?

ACP film should be removed soon after installation. It is a temporary working layer, not a permanent exterior covering. Confirm the PVDF or PE coating, expected outdoor exposure period and handover date. Direct sunlight, heat and temperature changes can make delayed removal harder. Low-temperature removal should be reviewed before handover, especially below 10 C. For China aluminum panel protective film orders used on facade projects, printed direction arrows and removal reminders can reduce installation errors.

TDS / Technical Range

Item

Typical Range / Customizable Value

Product groups

Profile film / sheet film / ACP panel film

Base film

PE / LDPE protective film

Adhesive system

Water-based acrylic / solvent acrylic / matched PSA

Film thickness

30-150 mic typical; confirm by finish and process

Roll width

Slit rolls for profiles / wide rolls for sheets and ACP

Roll length

Custom for manual use or automatic lines

Adhesion level

Low tack / medium tack / high tack

Surface compatibility

Anodized / smooth or rough powder coated / sand-textured / PVDF coated / PE coated

Colors

Transparent / blue / black and white / custom

Printing

Logo / direction arrows / handling notes

UV grade

Indoor / short-term outdoor / project-specific grade

Slitting and winding

Width tolerance / winding direction / roll flatness

Validation

180-degree peel / dwell time / aging / adhesion growth / edge lifting / residue inspection

Applications

  • Aluminium extrusion plants
  • Window and door profile manufacturers
  • Curtain wall profile processors
  • Aluminium sheet fabricators
  • ACP panel manufacturers
  • Facade contractors
  • Signage panel fabricators
  • Aluminium distributors

Customization Options

PET Film Supply Company can adjust thickness, roll width, roll length, slit-roll format, winding direction, color, tack, UV grade and printed content. For an aluminum profile protection film project, share extrusion width, finish, line speed and laminating method. For sheets and ACP panels, confirm dimensions, coating type, cutting steps, outdoor exposure and target removal date.

Before volume supply, approval should include a 180-degree peel test under agreed dwell time, aging review, residue inspection and edge lifting checks after cutting or drilling. Confirm artwork, roll identification and batch consistency before repeat orders.

How Should Adhesion Be Selected for Anodized and Powder Coated Aluminium?

Match adhesion to the actual finish, not only to film thickness. Smooth anodized aluminium and smooth powder coated profiles usually need stable low-to-medium tack with clean removal after transport. Rough powder coated or sand-textured profiles may require higher tack. Check a sample roll for initial peel force, adhesion growth after aging, residue risk and cut-edge stability.

FAQ

What film is suitable for anodized aluminium profiles?

Use PE protective film with tack validated on the actual finish. Review initial peel, aging behavior and clean removal before volume production.

Can ACP film remain on panels during outdoor installation?

Yes, when UV grade and removal window are agreed in advance. Remove it promptly after installation.

What should be checked for rough powder coated aluminium?

Check tack, edge lifting after cutting, residue after removal and transport stability.

What information is needed before requesting a quotation?

Provide aluminium type, finish, coating, width, roll length, thickness, application method, outdoor exposure, printing needs and removal date.